Server systems come in all sizes and they usually grow with the company’s needs.

Specifying UPS size for server systems has always been a challenging trade off. How many kVA? How many minutes of backup time? These are variables which many IT managers find difficult to handle, usually guess work and estimations are the few means available.

PowerKinetics’ PowerReactor1  Modular UPS changes all that. It is designed specifically to address the needs of most server room requirements. Its one-size-fits-all approach takes away the need for an IT manager to become a UPS expert in specifying a unit. Its power rating is based on the maximum power one is allowed to draw from a regular wall socket, the PowerReactor1  will be able to support!

The PowerReactor1  cabinets are available in tower and 19” rack-mount design. Want to increase backup time? No problem! Just slot in more battery modules and it is done! Maintaining the batteries will now be a snap. Just remove the battery modules while the system is still running. There is no shut off, truly hot-swappable!

For even longer backup time, the user has the option to connect external batteries to the Expandable Backup Cabinets, which are also available in tower and rack-mount designs. Let the PowerReactor1  eliminate all your power worries for the present and the future!

PowerReactor1  works with optional remote monitoring and management software. The software enables unattended system shutdown and remote monitoring of UPS operations.
........................................................................................................................

FEATURES

Maximum Power
PowerReactor1 has power rating of 5kVA, the maximum power allowed on most wall sockets.

Scalable
UPS backup time can be extended by adding battery modules, which just snaps into place - no need for wiring or tools.

Hot-Swappable
Battery modules can be inserted or removed with the system still on and protected. Maintenance or upgrading can be carried out without interrupting your computer operations.

Comprehensive Monitoring Of Operations
The LCD module function is to monitor the UPS operations. The PowerReactor1 can also work with an optional software for remote monitoring of UPS.